T35-11-5.6 直径560mm功率0.75KW 电机转速960r/min风量8471m3/h风压101pa电压380V-220V
风机的主要技术参数
机号 |
转速rpm |
叶片角度 |
风量m3/h |
风压Pa |
配用电机 |
A声级Db(A) |
|
型号 |
功率kw |
||||||
T35-11-2.8 |
2900 |
35 |
3202 |
232 |
YSF-6300 |
0.25 |
75 |
1450 |
35 |
1605 |
60 |
YSF-5024 |
0.12 |
62 |
|
T35-11-3.15 |
2900 |
35 |
4545 |
294 |
YSF-7122 |
0.55 |
79 |
1450 |
35 |
2273 |
74 |
YSF-5624 |
0.18 |
65 |
|
T35-11-3.55 |
2900 |
35 |
6542 |
373 |
YSF-8022 |
0.75 |
82 |
1450 |
35 |
3265 |
93 |
YSF-6314 |
0.18 |
68 |
|
T35-11-4 |
2900 |
35 |
9336 |
474 |
YF90S-2 |
1.1 |
85 |
1450 |
35 |
4687 |
119 |
YSF-7114 |
0.25 |
70 |
|
T35-11-4.5 |
1450 |
35 |
6658 |
150 |
YSF-7124 |
0.37 |
73 |
T35-11-5 |
1450 |
35 |
9133 |
185 |
YSF-8024 |
0.75 |
76 |
960 |
35 |
6104 |
81 |
YSF-8026 |
0.37 |
68 |
|
T35-11-5.6 |
1450 |
35 |
12812 |
232 |
YF90S-4 |
1.1 |
79 |
960 |
35 |
8471 |
101 |
YSF-8026 |
0.37 |
71 |
|
T35-11-6.3 |
1450 |
35 |
18250 |
294 |
YF100L-4 |
1.5 |
82 |
960 |
35 |
12082 |
128 |
YF90S-6 |
0.75 |
74 |
|
T35-11-7.1 |
1450 |
35 |
26120 |
373 |
YF112M-4 |
3 |
84 |
960 |
35 |
17296 |
164 |
YF90S-6 |
1.1 |
78 |
风机安装说明
1、 首先检查框架、风叶有无变形,扇叶转动是否灵活,有无摩擦现象。检查所有紧固件是否齐全、拧紧,应有防爆合格证编号。
2、 线路电压必须与电机上额定电压相符。
3、 用500V兆欧表检查电动机的绝缘电阻,其电阻值若小于50MΩ,则应用烘干法或短路电流法进行干燥处理,使其绝缘电阻大于5 MΩ。
4、 必须配用小型防爆开关做电源开关,或将普通开关安装于室外无爆炸性危险的地方。
5、 接电源的电缆外径应与密封圈相符,拧紧、压紧螺母后应保证密封圈与电缆间、出线间咀无间隙,否则将失去隔爆性能。
6、 装配时应保证防爆间隙小于0.2mm,更换电机轴承的润滑脂,其润滑脂牌号为ZG-2H复合钙基润。
7、 防爆电动机非接线部分不可随意拆卸,接线时,打开接线室的盖,穿入引线接到端子上,接好后,盖上盖拧紧螺钉使其隔爆面间隙小于0.2mm,再上紧出线器,使引线不能窜动。